Material Safety Data Sheet of Argon Gas
Share |


Identification
Product Name: Argon
Chemical formula: Ar
Product Use: Inert gas for storage of air-sensitive samples
Hazards Identification
-
Compressed gas
-
May cause asphyxiation in high concentrations
-
Vapor cause a stinging sensation
-
May cause dizziness when inhaled
-
Can cause vomiting
-
Unconsciousness
-
Cause headaches and drowsiness
-
Cause excitation and rapid breathing
-
Cause stinging of the nose and throat
First Aid Measures
-
In situations of high concentrations, asphyxiation may be caused which the victim may not be aware of.
-
In such cases, remove the victim to uncontaminated area.
-
Wearing protective clothing and self contained breathing equipment when helping the victim.
-
Keep victim warm and rested.
-
Apply artificial respiration if needed.
-
Take medical help
Fire Fighting Measures
-
Suitable extinguishing media should be used.
-
If possible, stop flow of product.
-
Stay away from the container.
-
Cool the container and the enclosed area with water from a protected position.
-
In closed space use self-contained breathing apparatus.
-
The usual protective gear should be worn by fire fighters.
-
Personnel should be evacuated to upwind area.
-
Remove containers from fire.
Accidental Release Measures
-
Evacuate the affected area.
-
Wear self-contained breathing apparatus.
-
Adequate air ventilation should be provided.
-
Try to stop the flow.
-
Avoid entering sewers, basements and any place where the product release is dangerous.
Handling & Storage Handling
-
Keep storage container below 50°C in a well ventilated place.
-
Suck back of water into the container must be avoided.
-
Do not allow back feed into the container.
-
Make use of specified equipment which is suitable for the gas.
-
Know the product's supply pressure and temperature while storing.
-
Follow supplier's container handling instructions.
-
Do not heat cylinder by any means.
-
Use check valve in discharge line to stop hazardous backflow into the cylinder.
-
Do not use oils or grease on gas-handling equipment.
-
After use, close main cylinder valve.
Tags:- Argon Gas Safety Data Sheet, MSDS Of Argon Gas
Looking for Gas Plants ?